Brand Name : CJ
Model Number : OBV5-B60
Certification : TUV/CE/UL/RoHS/REACH
Place of Origin : China
MOQ : 5pcs
Price : USD5-USD30
Payment Terms : T/T, Western Union,Paypal, L/C
Supply Ability : 1000pcs/day
Delivery Time : 10-30days
Packaging Details : Carton box. Carton size: 43*43*21cm
Product name : active lightning arrester
Poles Number : 1P,2P,3P,4P,(+NPE)
Imax : 60KA
Standard : IEC61643-1
Material : MOV/Nylon/PBT
In : 30kA
The active lightning arrester OBV5-B60 meet the type 1+2 requirement class according to IEC 61643-11. These devices protect low-voltage consumer systems from overvoltages of all types and are available in single-pole to four-pole versions. The use of high-performance varistors permits a rapid response time and a low protection level, without any line follow current. If circumstances are uncertain and there is a risk of fire from an overload, the internal cut-off unit disconnects the arrestor from the mains if necessary. In addition, the QR code printed on the arrestor allows direct access to the online installation instructions.
+ Connectable lightning current and surge arrestors
+ High arresting capacity up to 50 kA (10/350μs)
+ Visual status display
+ Available with optional remote signalling
+ Vibration-proof
+ Combination arrestors for buildings with lightning protection
+ Simple standard hat rail mounting
+ Labelled connections
+ Usable in systems with lightning protection class 3+4
| Mode | OBV5-B60 | ||
|  			 Maximum continuous voltage AC  |  			Uc | V | 275/320/385/440 | 
| SPD to EN 61643-11 | Type 1+2 | ||
|  			 SPD to IEC 61643-1  			 |  			class I+II | ||
|  			 Lightning impulse current (10/350μs)  			 |  			 			 Iimp  |  			kA | 12,5 | 
|  			 Nominal discharge current (8/20µs)  			 |  			 			 In  			 |  			kA | 30 | 
|  			 Maximum discharge current (8/20µs)  			 |  			 			 Imax  			 |  			kA | 60 | 
|  			 Voltage protection level  			 |  			 			 Up  			 |  			kV | <1,5/1,8/2,0/2,2 | 
|  			 Response time  			 |  			 			 tA  			 |  			ns | <25 | 
|  			 Maximum back-up fuse  			 |  			A | 125 | |
|  			 Temperature range  			 |  			 			 ϑ  			 |  			°C | -40℃~+85℃ | 
|  			 Protection rating  			 |  			IP 20 | ||
|  			 Max. cable cross-section flexible (fine-wire)  			 |  			mm² | 25 | |
|  			 Max. cable cross-section rigid (single wire/multi-wire)  			 |  			mm² | 35 | |


| 
                                             | 
                